Standby Server

hot_standby

Parameter description: Specifies whether to allow connections and queries on a standby server during its recovery.

This parameter is a POSTMASTER parameter. Set it based on instructions provided in Table 1 GUC parameters.

img NOTICE:

  • If this parameter is set to on, wal_level must be set to hot_standby. Otherwise, the database startup fails.
  • In an HA system, hot_standby cannot be set to off, because this setting can affect other features of the HA system.

Value range: Boolean

  • on indicates that connections and queries are allowed on the standby server during the recovery.
  • off indicates that connections and queries are not allowed on the standby server during the recovery.

Default value: on

max_standby_archive_delay

Parameter description: Specifies the wait period before queries on a standby server are canceled when the queries conflict with WAL processing and archiving in hot standby mode.

This parameter is a SIGHUP parameter. Set it based on instructions provided in Table 1 GUC parameters.

img NOTICE:

-1 indicates that the standby server waits until the conflicting queries are complete.

Value range: an integer ranging from -1 to INT_MAX. The unit is ms.

Default value: 3s (3000 ms)

max_standby_streaming_delay

Parameter description: Specifies the wait period before queries on a standby server are canceled when the queries conflict with WAL data receiving through streaming replication in hot standby mode.

This parameter is a SIGHUP parameter. Set it based on instructions provided in Table 1 GUC parameters.

img NOTICE:

-1 indicates that the standby server waits until the conflicting queries are complete.

Value range: an integer ranging from -1 to INT_MAX. The unit is ms.

Default value: 3s (3000 ms)

wal_receiver_status_interval

Parameter description: Specifies the maximum interval for notifying the primary server of the WAL Receiver status.

This parameter is a SIGHUP parameter. Set it based on instructions provided in Table 1 GUC parameters.

Value range: an integer ranging from 0 to INT_MAX. The unit is ms.

Default value: 5s (5000 ms)

hot_standby_feedback

Parameter description: Specifies whether a standby server is allowed to send the result of a query performed on it to the primary server, preventing a query conflict.

This parameter is a SIGHUP parameter. Set it based on instructions provided in Table 1 GUC parameters.

Value range: Boolean

  • on indicates that the ID of the oldest transaction active on standby servers will be sent to the primary server.
  • off indicates that the ID of the oldest transaction active on standby servers will not be sent to the primary server.

Default value: off

img NOTICE:

If this parameter is set to on, VACUUM on the primary server will not clean up tuples modified in transactions later than the oldest transaction active on standby servers. Therefore, the performance of the primary server will be affected.

wal_receiver_timeout

Parameter description: Specifies the maximum wait period for a standby server to receive data from the primary server.

This parameter is a SIGHUP parameter. Set it based on instructions provided in Table 1 GUC parameters.

Value range: an integer ranging from 0 to INT_MAX. The unit is ms.

Default value: 6s (6000 ms)

wal_receiver_connect_timeout

Parameter description: Specifies the timeout period for a standby server to connect to the primary server.

This parameter is a SIGHUP parameter. Set it based on instructions provided in Table 1 GUC parameters.

Value range: an integer ranging from 0 to INT_MAX/1000. The unit is s.

Default value: 2s

wal_receiver_connect_retries

Parameter description: Specifies the maximum attempts that a standby server connects to the primary server

This parameter is a SIGHUP parameter. Set it based on instructions provided in Table 1 GUC parameters.

Value range: an integer ranging from 1 to INT_MAX

Default value: 1

wal_receiver_buffer_size

Parameter description: Specifies the memory buffer size for the standby and secondary servers to store the received Xlog files.

This parameter is a POSTMASTER parameter. Set it based on instructions provided in Table 1 GUC parameters.

Value range: an integer ranging from 4096 to 1047552. The unit is KB.

Default value: 64MB (65536 KB)

primary_slotname

Parameter description: Specifies the slot name of the primary server corresponding to a standby server. This parameter is used for the mechanisms to verify the primary-standby relationship and delete WALs.

This parameter is a SIGHUP parameter. Set it based on instructions provided in Table 1 GUC parameters.

Value range: a string

Default value: empty

config_sync_interval

Parameter description: Specifies the interval for synchronizing configuration files between the primary and standby servers.

This parameter is a POSTMASTER parameter. Set it based on instructions provided in Table 1 GUC parameters.

Value range: an integer ranging from 0 to INT_MAX. The unit is ms.

Default value: 3600000 (which is one hour)

img NOTICE:

If this parameter is set to 0, the synchronization is not performed. To ensure that the synchronization is not performed when the primary and standby servers are started for the first time, set this parameter to 0 before the active and standby servers are started.